Техническая документация
Характеристики
Brand
FlukeТип продукции
Токовый щуп
Напряжение
600V
Ток
2.5kA
Цвет
Черный, Красный, Желтый
Тип наконечника щупа
Flexible Loop
Размер наконечника
25 mm
Диаметр гнезда щупа
7.5mm
Длина
6фут
Стандарты/одобрения
CAT III 1000 V, CAT IV 600 V
Страна происхождения
China
Информация о товаре
This current probe is a flexible loop accessory that extends AC measurement capability for compatible clamp meters to 2500 A. It provides a long lead for remote display viewing and a thin loop profile to access crowded wiring, while meeting rigorous overvoltage categories for field and industrial environments.
Combined probe‑and‑meter accuracy is specified as 3% Plus or minus 5 digits under optimum positioning when used with a compatible meter.
Position sensitivity adds up to ±2.0% error at 35.6mm from the optimum centre
closer offsets reduce the additional error.
With the probe cable located more than 10 cm from the coupling, external magnetic field rejection is rated at 40 dB.
The probe measures up to 1500 Hz with a frequency accuracy of 0.5% Plus or minus 5 digits.
Информация о наличии не успела загрузиться
тг 51 726,84
тг 51 726,84 Each (ex VAT)
1
тг 51 726,84
тг 51 726,84 Each (ex VAT)
Информация о наличии не успела загрузиться
1
Техническая документация
Характеристики
Brand
FlukeТип продукции
Токовый щуп
Напряжение
600V
Ток
2.5kA
Цвет
Черный, Красный, Желтый
Тип наконечника щупа
Flexible Loop
Размер наконечника
25 mm
Диаметр гнезда щупа
7.5mm
Длина
6фут
Стандарты/одобрения
CAT III 1000 V, CAT IV 600 V
Страна происхождения
China
Информация о товаре
This current probe is a flexible loop accessory that extends AC measurement capability for compatible clamp meters to 2500 A. It provides a long lead for remote display viewing and a thin loop profile to access crowded wiring, while meeting rigorous overvoltage categories for field and industrial environments.
Combined probe‑and‑meter accuracy is specified as 3% Plus or minus 5 digits under optimum positioning when used with a compatible meter.
Position sensitivity adds up to ±2.0% error at 35.6mm from the optimum centre
closer offsets reduce the additional error.
With the probe cable located more than 10 cm from the coupling, external magnetic field rejection is rated at 40 dB.
The probe measures up to 1500 Hz with a frequency accuracy of 0.5% Plus or minus 5 digits.