Техническая документация
Характеристики
Тип контроллера
Детектор
Тип датчика
Сульфид кадмия
Номинальное напряжение
220 → 270 В перем. тока
Тип монтажа
Дистанционный
Длина
57 мм
Ширина
31 мм
Высота
25мм
Активная мощность в ваттах
600 mW
Страна происхождения
United Kingdom
Информация о товаре
2-Part Luminaire Controller
Supplied with
2 nitrile gaskets
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.
Информация о наличии не успела загрузиться
Пожалуйста, перезагрузите страницу (ctrl+F5)
тг 7 397,85
Each (ex VAT)
1
тг 7 397,85
Each (ex VAT)
1
Техническая документация
Характеристики
Тип контроллера
Детектор
Тип датчика
Сульфид кадмия
Номинальное напряжение
220 → 270 В перем. тока
Тип монтажа
Дистанционный
Длина
57 мм
Ширина
31 мм
Высота
25мм
Активная мощность в ваттах
600 mW
Страна происхождения
United Kingdom
Информация о товаре
2-Part Luminaire Controller
Supplied with
2 nitrile gaskets
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.