Техническая документация
Характеристики
Brand
ParkerТип продукции
Пневматический таймер
Сертификация опасной зоны
Conforming to certificate LCIE 866115X, EExe ll T4
Тип монтажа
DIN-рейка
Минимальное рабочее давление
3bar
Максимальное рабочее давление
8 bar
Минимальная рабочая температура
-15°C
Максимальная рабочая температура
60°C
Стандарты/одобрения
EN 50014 dated March 1977 (NFC 23514 dated May 1982), EN 50019 dated March 1977 (NFC 23519 dated May 1982)
Информация о товаре
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.
Информация о наличии не успела загрузиться
тг 68 739,66
тг 68 739,66 Each (ex VAT)
1
тг 68 739,66
тг 68 739,66 Each (ex VAT)
Информация о наличии не успела загрузиться
1
Техническая документация
Характеристики
Brand
ParkerТип продукции
Пневматический таймер
Сертификация опасной зоны
Conforming to certificate LCIE 866115X, EExe ll T4
Тип монтажа
DIN-рейка
Минимальное рабочее давление
3bar
Максимальное рабочее давление
8 bar
Минимальная рабочая температура
-15°C
Максимальная рабочая температура
60°C
Стандарты/одобрения
EN 50014 dated March 1977 (NFC 23514 dated May 1982), EN 50019 dated March 1977 (NFC 23519 dated May 1982)
Информация о товаре
Timer Module
A pneumatic timer consists of a solenoid coil/core, operating spring, timing disk, filter and diaphragm. The core moves up into the coil when it has been energized and this leads to pressure on the diaphragm. The diaphragm moves into the top chamber which un-traps the air through the timing disk. By altering the needle valve you can adjust the amount of delay.
Logic Systems
Logic units are best thought of as miniature valves, whose purpose is to influence the behaviour of larger power valves. They achieve this by producing and receiving output and input signals, using the common air supply. In this way, they are able to monitor and control a whole sequence of operations with great accuracy and repeatability.